Useful tips
Hybrid inverter 5 kW + LiFePO4 battery: how to calculate autonomous power supply for a house for 12–24 hours

A 5 kW hybrid inverter combined with a LiFePO4 battery allows you to maintain the operation of a refrigerator, gas boiler, lighting, router and other household appliances during power outages. But for the system to truly provide autonomy for 12–24 hours, you need to correctly calculate the battery capacity, take into account the starting currents of the devices and configure charging. Let's consider what equipment to choose for an apartment or private house and how much energy will be needed for a comfortable life without electricity.
How a 5 kW backup power system works
The core of the system is a hybrid inverter that manages the flow of electricity between the grid, the battery, the consumers and, if available, the solar panels. When the power supply fails, the device switches to battery power according to its design and settings.
A typical system consists of the following components:
- 5 kW hybrid inverter — converts the battery's direct current into 230 V alternating current.
- LiFePO4 battery — accumulates electricity and ensures the operation of equipment during outages.
- BMS — a battery management system that monitors voltage, current, and temperature and provides protection in modes specified by the manufacturer.
- Circuit breakers and protective devices — ensure safe operation of the electrical installation.
- Solar panels — an optional component that allows you to replenish energy reserves during the day under appropriate weather conditions.
To see the finished solution, you can view 5 kW hybrid solar power plant kit with LiFePO4 battery.
It is important to understand that inverter power and battery capacity are different characteristics. A 5 kW inverter shows what load it can provide under the appropriate conditions, while battery capacity determines how much energy can be used before it is discharged.
How to calculate battery capacity for 12–24 hours of autonomy
You should start selecting equipment not by choosing the most expensive battery, but by calculating your daily electricity consumption.
For each device, you need to know its average power and approximate operating time. Energy is calculated using the formula:
Energy, Wh = power, W × operating time, h.
For example, if a router consumes 10 watts and operates for 24 hours, its daily consumption will be 240 Wh, or 0.24 kWh.
Example of consumption of major household appliances
Below is a rough estimate for a home where only essential appliances are running during a power outage.
| Instrument | Average consumption | Working hours | Energy per day |
|---|---|---|---|
| Refrigerator | 40 W on average | 24 hours | 0.96 kWh |
| Gas boiler with pump | 100 W | 8 hours | 0.80 kWh |
| LED lighting | 40 W | 6 hours | 0.24 kWh |
| Router and ONU | 12 W | 24 hours | 0.29 kWh |
| TV | 100 W | 3 hours | 0.30 kWh |
| Laptop | 60 W | 4 hours | 0.24 kWh |
| Together | — | — | 2.83 kWh |
This is an example, not a universal indicator. A refrigerator consumes energy cyclically, and its actual consumption depends on the model, the temperature in the room and the frequency of door opening. A gas boiler also does not always work continuously: consumption depends on the heating mode and the operation of the circulation pump.
For a more accurate calculation, it is worth adding a margin for inverter losses, equipment's own consumption, and unforeseen loads.
How much energy is needed for 12 and 24 hours
If the listed devices consume approximately 2.83 kWh per day, half of the day will require about 1.42 kWh, excluding losses.
Indicative needs for different scenarios:
| Usage mode | Consumption in 12 hours | Consumption per 24 hours |
|---|---|---|
| Minimum: boiler, router, lighting | 0.8–1.2 kWh | 1.6–2.4 kWh |
| Basic: refrigerator, boiler, electricity, internet | 1.2–1.8 kWh | 2.4–3.6 kWh |
| Comfortable: additionally a TV and a laptop | 1.5–2.2 kWh | 3.0–4.4 kWh |
These values are guidelines. Actual consumption should be determined based on the characteristics of specific appliances and real usage patterns.
Which LiFePO4 battery to choose
LiFePO4 is a lithium iron phosphate battery technology that is widely used in backup power systems. These batteries have a high cycle life and can withstand regular charge and discharge cycles when used according to the manufacturer's recommendations.
For home inverters, batteries with a nominal voltage of 48 or 51.2 V are often used. The specific voltage must meet the requirements of the inverter.
Comparing batteries by capacity
| Characteristic | 51.2 V, 50 Ah | 51.2 V, 100 Ah | 51.2 V, 200 Ah |
|---|---|---|---|
| Nominal energy consumption | 2.56 kWh | 5.12 kWh | 10.24 kWh |
| Approximate useful energy at 90% depth of discharge | 2.30 kWh | 4.61 kWh | 9.22 kWh |
| Estimated inverter output energy at 90% efficiency | 2.07 kWh | 4.15 kWh | 8.30 kWh |
| Typical purpose | Small loads | Basic backup power | Long battery life |
The calculation assumes a depth of discharge of 90% and an inverter efficiency of 90%. This is a hypothetical example: the actual available energy depends on the allowable discharge, temperature, load current, battery condition and inverter characteristics.
What does this mean in practice?
If the house consumes 2.83 kWh per day, a 5.12 kWh battery, based on the above assumptions, will provide approximately 17.6 hours of operation. Calculation: 4.15 ÷ (2.83 ÷ 24) ≈ 35.2 hours? No — it is important to correctly distinguish between average consumption and daily demand.
With a daily consumption of 2.83 kWh, the average power is about 118 W. Then the reserve of 4.15 kWh is theoretically enough for about 35 hours. However, in real conditions, the time may be less due to additional loads, the inverter's own consumption, peak loads and other losses.
For a guaranteed 24 hours, it is better to design the system with a margin, rather than selecting a battery close to theoretical consumption.
LiFePO4 or lead-acid battery
For backup power, you can use AGM, GEL or LiFePO4. However, these technologies differ not only in price, but also in permissible depth of discharge, resource and operating requirements.
| Criterion | AGM / GEL | LiFePO4 |
|---|---|---|
| Initial cost | Usually lower | Usually higher |
| Useful part of the tank | It is often advisable to use about 50% to conserve resources | Often 80–90% or another value according to the passport is allowed |
| Cycle life | Usually smaller | Usually much larger |
| Weight | Higher for the same nominal energy capacity | Lower |
| Charging speed | Often limited by battery specifications | Can be higher if allowed by BMS and manufacturer |
| Battery control | Depends on the system | Usually built-in BMS |
| Working in sub-zero temperatures | Depends on type and conditions | Charging most models below 0 °C is prohibited without special heating or manufacturer permission. |
For a system that regularly operates during outages, LiFePO4 is often a more practical solution due to its lifespan and ability to use most of the stored energy. However, the comparison should be based on the cost of useful energy over the entire life cycle, not just the purchase price.
How to take into account the starting currents of a refrigerator, boiler and pump
Household appliances with electric motors can briefly consume significantly more energy during startup than in normal operation. These include refrigerators, pumps, and some circulation systems.
| Equipment | Estimated operating capacity | What to consider when launching |
|---|---|---|
| Refrigerator | 80–200 W | The compressor may require several times more power |
| Gas boiler with pump | 80–200 W | Check voltage form and grounding requirements |
| Well pump | 500–1500 W | Starting load can be several times higher |
| LED lighting | 20–100 W total | Take into account the short-term starting current of the drivers |
| TV and router | 20–150 W total | Usually a small load |
The values in the table are for guidance only. Before connecting, you should check the nameplate, passport or measure the actual characteristics of the equipment.
A 5 kW inverter will not necessarily be able to start any 2 kW pump: it all depends on the starting current, the short-term overload capacity of the inverter and the battery capabilities. The maximum discharge current of the BMS and the permissible current of the cables are also important.
If the refrigerator and the pump are started at the same time, their starting loads may coincide. Therefore, it is necessary to check not only the nominal 5 kW, but also the permissible peak power and overload duration according to the documentation of the specific model.
Setting the charging current in the inverter
Properly configured charging helps to use the battery without exceeding the permissible currents and voltages. Different parameters are available in the Deye, SolaX and LuxPower models, and the exact names of the menu items depend on the model and software version.
First of all, you need to check the following settings:
- Battery type. Select LiFePO4 or the appropriate lithium battery mode, if provided by the manufacturer.
- Communication with BMS. If you have a compatible CAN or RS485 interface, use the manufacturer's recommended cable and the correct protocol.
- Maximum charging current. It must not exceed the limits of the battery, BMS and inverter.
- Charging and disconnection voltages. They need to be set according to the battery's passport, not according to universal values from the Internet.
- Temperature protection. Charging must be blocked under conditions that the manufacturer identifies as unsafe.
For example, for a 51.2 V, 100 Ah battery, a current of 20 A corresponds to approximately 0.2 C. This is only an illustration of the calculation, not a universal recommendation: the permissible charging current for a particular battery may be different.
At a voltage of around 51.2 V, a charging current of 20 A corresponds to a power of around 1 kW. All other things being equal, charging with a current of 40 A will require approximately twice as much power, but will only be permissible if all system components allow it.
You also need to consider the power available from the grid or solar panels, and the home's consumption during charging. Don't set the maximum current just for the sake of a quick charge recovery.
How to ensure autonomy for 24 hours
For long-term operation without electricity, it is important not only to increase battery capacity, but also to manage consumption.
Practical procedure:
- Identify appliances that should be running constantly: refrigerator, boiler, internet, and lighting.
- Measure or calculate their daily intake.
- Add a margin for conversion losses and the inverter's own consumption.
- Choose a battery with sufficient useful energy capacity.
- Check the inverter peak power, BMS discharge current and pump starting characteristics.
- If necessary, add solar panels to replenish energy during the day.
If your home uses 3-4 kWh per day, a 5.12 kWh battery may be sufficient in economy mode, but it won't provide guaranteed daily autonomy in every situation. For more energy storage, consider a 10.24 kWh battery or two compatible batteries of smaller capacity.
At the same time, solar panels do not guarantee full charging in winter: the result depends on the length of daylight, cloudiness, panel orientation, shading, and available system power.
Frequently asked questions
Will a 5 kW hybrid inverter be enough for the whole house?
For many household appliances, this power is sufficient if their simultaneous load does not exceed the permissible values. An electric boiler, kettle, electric stove and a powerful pump can quickly exhaust the available power reserve, so their simultaneous operation must be planned.
What battery is needed for a boiler and refrigerator?
The daily consumption, required autonomy time, system voltage and permissible discharge current are important for selection. For longer operation, it is usually more appropriate to consider LiFePO4 at 48/51.2 V, but the final capacity must be determined by calculation.
Can I charge a LiFePO4 battery in winter?
Most LiFePO4 batteries are not allowed to be charged below 0°C unless the manufacturer specifically states otherwise. For cold room installation, check temperature limits, heating and BMS functionality.
Can I add another battery later?
This depends on the inverter model, battery compatibility, battery voltage, BMS, and manufacturer’s paralleling requirements. It is best to choose a system in advance that can be safely expanded.
5 kW hybrid inverter together with a LiFePO4 battery - a practical option for backup power for an apartment or private house. However, the duration of autonomous operation is determined primarily by the battery capacity and actual consumption, and not only by the inverter power.
A smaller battery may be sufficient for 12 hours of autonomy, while for stable operation throughout the day, you need to consider the energy reserve, starting currents and the possibility of recharging. Correct calculation and compatibility of all components will help you choose a system that will meet the real needs of the house.
When choosing equipment, it is worth comparing not only the price, but also the characteristics of the inverter, battery life, BMS capabilities, warranty and installation conditions. This approach allows you to get reliable backup power without unnecessary costs.